Applications & Product Lines
Search
Login
Support
Filter
Cart
Language
Currency
Produkt-Filter
product-filter
operating range
safety
outputs
supply voltage
enclosure rating
Prices for customers after login
Safety
Opto edge pair of safety light curtain system cegard/Lift, standard version, meets DAA standard of 1990.
Safety light curtain system cegard/Lift-LI, can be used in combination with elevator controller, which enables safety-related monitoring of the system.
Opto edge pair of safety light curtain system cegard/Lift, fully potted version, meets DAA standard of 1990.
Control unit of safety light curtain system cegard/Lift LX for systems with 16 elements per opto edge pair cegard/Lift
Safety light curtain system cegard/Lift-LX, for retrofitting a freight elevator without elevator cabin doors with existing elevator controller, 2 entrances, for opto edges with 16 elements
Entrance and exit monitoring
EN 81/20 compliant light curtain for safeguarding elevator cabin doors, pre-wired for plug-and-play for modernizing and retrofitting, 36 elements, mechanical length 2 m.
EN 81/20 compliant light curtain for safeguarding elevator cabin doors, direct connection to state-of-the-art electronic controllers, 36 elements, mechanical length 2 m.
EN 81/20 compliant light curtain for safeguarding elevator cabin doors, pre-wired for plug-and-play for modernizing and retrofitting, 36 elements, mechanical length 1.9 m
Safety light curtain for industrial doors with dynamic blanking, FSS/OSE output, in combination with pressure contact edge as safety device C+D according to standard EN 12453
Safety light curtain for industrial doors with dynamic blanking, as safety device E according to standard EN 12453, combined output with push-pull and FSS.
Safety light curtain for industrial doors with dynamic blanking, push-pull output, in combination with pressure contact edge as safety device C+D according to standard EN 12453
Safety light curtain for industrial doors with dynamic blanking, as safety device E according to standard EN 12453, combined output with push-pull and FSS
Opening / Activation
Comfort sensor that can be operated without a background, programmed using a teach-in method
Comfort sensor that can be operated without a background, programmed using a potentiometer.
Comfort sensor that can be operated without a background, programmed using automatic power-up calibration.
Comfort sensor, especially for parking lot barrier applications, that can be operated without a background, programmed using a teach-in method.
Comfort sensor, especially for truck detection, that can be operated without a background, programmed using a potentiometer.
3D sensor for detecting people and objects approaching, especially for escalators.
3D sensor for detecting people and objects approaching, cross-traffic is ignored, especially for escalators.
3D sensor for detecting people and objects approaching with extended power supply unit, especially for escalators.
3D sensor for detecting people and objects in the detection area, corner mounting.
3D sensor for detecting people and objects in the detection area, central mounting.
Monitoring of the entrance area, 3D sensor as a supplement to light curtains on automatic elevator doors.